• May 28, 2024
 
  

Advantages of A Thermal Dispersion Switch For Pump Protection

Running pumps in a dry state can damage parts or cause cavitation in centrifugal pumps. Replacement parts can add up to thousands of dollars. These costs do not include inefficiencies in pump operation or downtime that affects production or operation.

Technologies Used for Pump Protection

There are many technologies that can perform the function of pump protection. Flow meters can be used, but a continuous flow measurement is not always necessary and flow meters typically cost more than switches. Mechanical flow switches use a mechanical operation to actuate a relay; however, moving parts can be subject to wear and increased maintenance over time, and if a viscous liquid or build-up is present, reliability of the switch may be adversely affected.

Tuning forks and ultrasonic gap switches are alternative technologies that are used for pump protection. It is inherent in the technologies that the fork or gap must be wet or dry for detection. Therefore, they cannot detect decreasing flow rates and the opening creates room for possible plugging.

Blog_Image_Thermatel-Pump-Protection_900x602         

Why Choose a Thermal Dispersion Switch?

A thermal dispersion switch is ideally suited for pump protection applications due to the capability to detect low flow conditions. Thermal dispersion switches use similar principles as thermal mass flow meters. Fluid carries heat away from the probe tip reducing the temperature difference between a heated resistance temperature detector (RTD) and a reference RTD. As the temperature difference increases or decreases due to heat transfer, the set point is reached and the relay de-energizes. Manufacturers will refer to the switch being in “alarm” at set point. How the relay is wired (NC-CO or NO-CO) depends on the needs of the application.

With thermal dispersion, the user gets the most robust feature set and flexibility. The technology’s advantages include:

  • No moving parts, requiring less maintenance
  • Many probe types for water or more viscous liquids
  • Installation in horizontal or vertical lines, removing need to be installed top dead center
  • Optional remote mount electronics
  • Hot tap options available
  • Low flow detection as opposed to dry pipe
  • Current output for trending and fault indication
  • Temperature compensation to reduce set point drift under varying operating temperatures

 

Blog_Cover_Thermatel-Pump-Protection_750x500

White Paper: Advantages of Thermal Dispersion Switches for Pump Protection

Download our white paper below where we discuss thermal dispersion switches in detail; including probe types, installation and electronics.

Download

October 15, 2025

AMETEK Magnetrol USA LLC Appoints TechStar LLC as Exclusive Channel Partner for Oklahoma

March 28, 2025

New Partnership Serving The U.S. Midwest Region

March 10, 2025

The New Old-Fashioned: Enhancing Traditional Level Measurement Techniques

February 24, 2025

Cut Monitor Technologies and Factors that Affect Their Performance

February 12, 2025

Plugged Chute Detection

January 20, 2025

Why Drexelbrook's Level Technology Stands Out Universally

November 7, 2024

BrightTEK™ – Transforming Remote Monitoring and Industrial Efficiency

October 23, 2024

Maximize ROI with Drexelbrook® branded Water Cut Meters: An Investment That Pays Off

October 10, 2024

Why Mechanical Instruments Remain Essential for Industrial Level Measurement

September 23, 2024

Case Study: Not All Guided Wave Radar Transmitters are Created Equal