Liquid nutritional supplement

Level Measurement of a liquid nutritional supplement in a vessel that feeds a reservoir on a filling machine.

Challenge

Level was being measured by a competitors capacitance probe. The vessel is a tall narrow tube that feeds product to a high speed filling machine. Product enters the vessel through a side-mounted tee connection. The measurement was unreliable, resulting in improperly filled containers. This resulted in lost production and time while certain containers did not meet spec.
After examining the application, we concluded that the fluid entering through the tee connection was splashing against the probe, thus giving false level readings.

Solution

This was a perfect application for an Eclipse Model 706 with the coaxial probe. Since the measurement is made entirely within the probe, it is unaffected by splashing or any disturbance outside the probe. Additionally, the fluid is not viscous so that did not cause a concern.
An Eclipse with coaxial probe was installed, configured with PACTware™ and worked perfectly from day one. The level measurement was accurate and reliable.

Related products

Other applications

Do you want personal advice for your specific control process? 

Contact your local AMETEK Level Measurement Solutions representative!

Find my local representative

Related articles

October 15, 2025

AMETEK Magnetrol USA LLC Appoints TechStar LLC as Exclusive Channel Partner for Oklahoma

March 28, 2025

New Partnership Serving The U.S. Midwest Region

March 10, 2025

The New Old-Fashioned: Enhancing Traditional Level Measurement Techniques

February 24, 2025

Cut Monitor Technologies and Factors that Affect Their Performance

February 12, 2025

Plugged Chute Detection

January 20, 2025

Why Drexelbrook's Level Technology Stands Out Universally

November 7, 2024

BrightTEK™ – Transforming Remote Monitoring and Industrial Efficiency

October 23, 2024

Maximize ROI with Drexelbrook® branded Water Cut Meters: An Investment That Pays Off

October 10, 2024

Why Mechanical Instruments Remain Essential for Industrial Level Measurement

September 23, 2024

Case Study: Not All Guided Wave Radar Transmitters are Created Equal