In-Line Fluid Detection Eliminates Pump Damage

Progressing cavity pumps are used for conveying thick slurries and other process fluids with high solids content. These pumps rely on a constant supply of fluid for lubrication. If the pump runs dry, the internal components and motor can be damaged requiring expensive repairs and costly down time.

The solution to this costly problem is to monitor the pump suction and shut it down before it runs dry. A number of creative approaches to protecting against run dry have been used including measuring current draw of the motor or measuring torque on the drive shaft. Both these methods react to a change due to loss of material in the pump however, shut down will only occur after the pump has started running dry which is often too late to prevent damage. At a minimum it will decrease pump life. Also, since current and torque are not linear functions of friction, it is difficult to ensure pump shut down prior to damage.

Monitoring the process material being pumped is a much better approach and can shut down the pump when the up stream leg becomes empty. This will ensure that the pump will not be run in a dry condition. The most common methods for measuring the absence of fluid are pressure, flow, conductance, or RF Admittance level switches.

You need to ask, “what is the total cost of an installed pump”? “What does a typical pump rebuild cost”? “What is the cost per hour of downtime”? A reliable monitoring switch is obviously a wise investment, which will pay for itself many times over by extending pump life and preventing costly damage.

Level Measurement Technologies
The following is an assessment of the most common point level switch technologies used for pump shut down control.

Pressure Switches
Pressure switches measure the increase or decrease in head pressure on a diaphragm. A reduction of head indicates an emptying or empty pipe and signals the pump to shut down. Pressure switches are notorious for failure due to material plugging the diaphragm. A plugged diaphragm will not respond to changes in the pipe emptying resulting in damage to the pump. Pressure switches are an unreliable choice for pump protection.

Flow Switches
There are several types of flow switches available including mechanical and thermal dispersion switches. Both of these technologies require a sensor inserted into the flow stream, which will contribute to pipe line plugging.

Mechanical flow switches utilize a paddle or target on the end of a pivot arm. Material flow deflects the target indicating flow. Mechanical devices have a major drawback in that they are mechanical. The pivot and spring assemblies are susceptible to wear and corrosion. Solids in the process material being measured can also damage theassembly.

Thermal dispersion switches are made up of two thermal wells inserted into the process material. The first thermal well contains a reference sensor that monitors the process temperature. The second thermal well includes a heater that is the active sensor. As material flows past the assembly, Heat is dispersed from the active sensor reducing the differential between the active and reference sensors and indicating process flow.

Thermal dispersion sensors, being an insertion type technology, are subject to wear and impact damage from solids in the process material. Thermal dispersion sensors are also relatively slow in response time allowing the pump to run dry prior to shutting down, resulting in reduced pump life.

Conductivity
Conductivity switches are sometimes used in pump protection however; they are a poor choice for a number or reasons. Conductivity switches are notorious for material bridging between the active electrode and ground resulting in a false indication of level. This would allow the pump to run dry. The process material may leave a hard, insulating coating on the electrode as it dries or an oil coating, insulating the conductivity sensor. 

The insulation prevents the switch from passing current causing it to not “see” material shutting the pump down when there is plenty of lubricant available.

RF Admittance – The Best Choice!
The Drexelbrook ClearLine level switch is the best choice for pump protection. The ClearLine sensing element mounts between two flat-faced flanges in the process piping providing a flush, non-intrusive sensor that does not contribute to pipe blockages. The sensing element has no moving parts and is a robust, industrial design.

The Drexelbrook proven and reliable RF driven-shield circuitry ignores even heavy coatings on the sensing element eliminating false indication of process material. Thousands of units have been installed and many years of proven field results. The Clearline requires no routine maintenance. Sensors are available to fit most pipes from 1 inch up to 10 inches in diameter. Each ClearLine level switch is factory calibrated to provide reliable, repeatable performance regardless of changes in process fluids and coatings, or variations in temperature or density.

The ClearLine from Drexelbrook is the most reliable, no-maintenance choice for pump protection applications.

 

Related products

Displacer Switch
Magnetrol

Displacer switches – single, dual and tri-switch series

Single-Stage Switches

Series A10 displacer type level measurement units are wide differential units calibrated to actuate as a liquid level reaches a given displacer and to deactuate when the level reaches a second displacer. Single stage, wide differential displacer switches are factory calibrated yet field-adjustable to operate over a wide level differential band.

The minimum differential band is approximately 6 inches (152 mm) in water and varies somewhat with liquid specific gravity. The maximum differential is determined by the length of the displacer suspension cable. Series A15 units are calibrated to operate over a narrow level differential band and are ideally suited for liquid level alarm applications on either high or low level.

Dual-Stage Switches

Series B10 displacer type level measurement units are wide differential tandem switches that are factory calibrated with a choice of several switch operating sequences designed to meet virtually any application.

Series B15 units are narrow differential tandem switches that are factory calibrated. Each switch actuates at a different level.

Tri-Stage Switches

Series C10 displacer type level measurement units utilize three electrically separate control signals in a selected sequence in response to liquid level changes.

Series C15 units are wide differential switches with a choice of several operating sequences combining wide and narrow level differential and are factory calibrated.

Other applications

Do you want personal advice for your specific control process? 

Contact your local AMETEK Level Measurement Solutions representative!

Find my local representative

Related articles

October 15, 2025

AMETEK Magnetrol USA LLC Appoints TechStar LLC as Exclusive Channel Partner for Oklahoma

March 28, 2025

New Partnership Serving The U.S. Midwest Region

March 10, 2025

The New Old-Fashioned: Enhancing Traditional Level Measurement Techniques

February 24, 2025

Cut Monitor Technologies and Factors that Affect Their Performance

February 12, 2025

Plugged Chute Detection

January 20, 2025

Why Drexelbrook's Level Technology Stands Out Universally

November 7, 2024

BrightTEK™ – Transforming Remote Monitoring and Industrial Efficiency

October 23, 2024

Maximize ROI with Drexelbrook® branded Water Cut Meters: An Investment That Pays Off

October 10, 2024

Why Mechanical Instruments Remain Essential for Industrial Level Measurement

September 23, 2024

Case Study: Not All Guided Wave Radar Transmitters are Created Equal