Series B73 and series 75 sealed external cage liquid level switches

Series B73 and series 75 external cage type level switches are completely self-contained units designed for side mounting to a tank or vessel with threaded, socket weld or flanged pipe connections. These float-actuated controls have proven their reliability in process control for decades.

Technology

External cage switches

A permanent magnet is attached to a pivoted switch actuator. As the float/displacer rises following the liquid level, it raises the attraction sleeve into the field of the magnet, which then snaps against the non-magnetic enclosing tube, actuating the switch. The enclosing tube provides a static pressure boundary between the switch mechanism and the process. On a falling level, the float/displacer deactivates the switch.
External Cage
  • Features
  • Applications
  • Operating principle
  • Approvals
  • Downloads

  • Carbon steel or stainless steel welded float chamber
  • Service pressures up to 2240 psig (154 bar)
  • Process temperatures up to +1000 °F (+538 °C)
  • Specific gravity ratings as low as 0.32
  • Available switch styles including dry contact, hermetically sealed and pneumatic
  • Single or multiple switch mechanisms available
  • Optional high temperature insulation available
  • Choice of switch mechanism: ◦ Dry contact ◦ Hermetically sealed ◦ Pneumatic
  • Choice of switch mechanism enclosure: ◦ TYPE 4X/7/9 Class I, Div. 1, Groups B, C & D, polymer coated aluminum ◦ NEMA 1, carbon steel for pneumatics
  • Choice of tank connection: ◦ 1", 1½" or 2" NPT ◦ 1", 1½" or 2" flanged side/side ◦ 1", 1½" or 2" flanged side/bottom ◦ 1", 1½" or 2" socket welds

Options

  • Interface calibration
  • Extreme temperature modifications
  • Customized installation dimensions
  • Customized exterior surface preparation and finish
  • Customized actuation levels
  • Vent and drain connections
 

The buoyancy force of a process liquid on the float causes the float to ride on the liquid surface. The movement of the float with the liquid level moves an attraction sleeve into the field of the switch magnet, pulling the magnet toward the sleeve and actuating the switch.

ATEX Ex d, Ex ia
CCOE Ex d
CSA XP
FM XP
EAC (GOST)
Ex d, Ex ia
IEC Ex d, Ex ia
Inmetro Ex d
Korea Ex d
NEPSI
Ex d
SIL SIL 2 (1oo1)

Other approvals are available. Consult factory for more details.

  • Approvals and Certificates
    • ATEX Ex d Certificate - Mechanical Switches
    • FM Certificate - Mechanical Switches - US
    • FMEDA Report Flanged Sealed Cages
    • IECEx Certificate - Mechanical Switches
    • FM Certificate - Mechanical Switches - Canada
  • Instruction Manual
    • USA Model B73 - Series 75 I&O Manual
    • English Model B73 I&O Manual
    • English Series 75 I&O Manual
  • Product Catalogs
    • USA Model B73 - Series 75 Product Catalog
    • English Model B73 - Series 75 Product Catalog

Related Articles

October 15, 2025

AMETEK Magnetrol USA LLC Appoints TechStar LLC as Exclusive Channel Partner for Oklahoma

March 28, 2025

New Partnership Serving The U.S. Midwest Region

March 10, 2025

The New Old-Fashioned: Enhancing Traditional Level Measurement Techniques

February 24, 2025

Cut Monitor Technologies and Factors that Affect Their Performance

February 12, 2025

Plugged Chute Detection

January 20, 2025

Why Drexelbrook's Level Technology Stands Out Universally

November 7, 2024

BrightTEK™ – Transforming Remote Monitoring and Industrial Efficiency

October 23, 2024

Maximize ROI with Drexelbrook® branded Water Cut Meters: An Investment That Pays Off

October 10, 2024

Why Mechanical Instruments Remain Essential for Industrial Level Measurement

September 23, 2024

Case Study: Not All Guided Wave Radar Transmitters are Created Equal

Do you want personal advice for your specific control process?

Contact us directly or reach out to your local AMETEK Level Measurement Solutions representative!

FIND MY LOCAL REPRESENTATIVE